@ -161,4 +161,37 @@ BOOST_FIXTURE_TEST_CASE(logging_LogPrintMacros_CategoryName, LogSetup)
|
|
|
|
|
BOOST_CHECK_EQUAL_COLLECTIONS(log_lines.begin(), log_lines.end(), expected.begin(), expected.end());
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
BOOST_FIXTURE_TEST_CASE(logging_SeverityLevels, LogSetup)
|
|
|
|
|
{
|
|
|
|
|
LogInstance().EnableCategory(BCLog::LogFlags::ALL);
|
|
|
|
|
|
|
|
|
|
LogInstance().SetLogLevel(BCLog::Level::Info);
|
|
|
|
|
LogInstance().SetCategoryLogLevel(/*category_str=*/"net", /*level_str=*/"info");
|
|
|
|
|
|
|
|
|
|
// Global log level
|
|
|
|
|
LogPrintLevel(BCLog::HTTP, BCLog::Level::Info, "foo1: %s\n", "bar1");
|
|
|
|
|
LogPrintLevel(BCLog::MEMPOOL, BCLog::Level::Debug, "foo2: %s. This log level is lower than the global one.\n", "bar2");
|
|
|
|
|
LogPrintLevel(BCLog::VALIDATION, BCLog::Level::Warning, "foo3: %s\n", "bar3");
|
|
|
|
|
LogPrintLevel(BCLog::RPC, BCLog::Level::Error, "foo4: %s\n", "bar4");
|
|
|
|
|
|
|
|
|
|
// Category-specific log level
|
|
|
|
|
LogPrintLevel(BCLog::NET, BCLog::Level::Warning, "foo5: %s\n", "bar5");
|
|
|
|
|
LogPrintLevel(BCLog::NET, BCLog::Level::Debug, "foo6: %s. This log level is lower than the category-specific one.\n", "bar6");
|
|
|
|
|
LogPrintLevel(BCLog::NET, BCLog::Level::Error, "foo7: %s\n", "bar7");
|
|
|
|
|
|
|
|
|
|
std::vector<std::string> expected = {
|
|
|
|
|
"[http:info] foo1: bar1",
|
|
|
|
|
"[validation:warning] foo3: bar3",
|
|
|
|
|
"[rpc:error] foo4: bar4",
|
|
|
|
|
"[net:warning] foo5: bar5",
|
|
|
|
|
"[net:error] foo7: bar7",
|
|
|
|
|
};
|
|
|
|
|
std::ifstream file{tmp_log_path};
|
|
|
|
|
std::vector<std::string> log_lines;
|
|
|
|
|
for (std::string log; std::getline(file, log);) {
|
|
|
|
|
log_lines.push_back(log);
|
|
|
|
|
}
|
|
|
|
|
BOOST_CHECK_EQUAL_COLLECTIONS(log_lines.begin(), log_lines.end(), expected.begin(), expected.end());
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
BOOST_AUTO_TEST_SUITE_END()
|
|
|
|
|